Aopos AS230+ Manual de usuario

Busca en linea o descarga Manual de usuario para Lectores De Códigos De Barras Aopos AS230+. Aopos AS230+ User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Series Barcode Scanner

User Manual Version: _UM_EN_V3.2.8 AOPOSAS250+/AS230+Series Barcode Scanner

Pagina 2

6 Parts of the scanner Figure 1 ① LED ② Exit window ③ Trigger ④ Cable interface port ⑤ Release-hole of the cable ⑥ Beeper Figure 2 Remove the

Pagina 3 - Contents

7 Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper

Pagina 4

8 Installation - USB The scanner attaches directly to a USB host, and is powered by it. No additional power supply is required. 1.

Pagina 5 - Technical specifications

9 Scanning modes The scanner has two scanning modes: hand-held and auto-detection. When the scanner is scanning, ensure the scan line crosses every

Pagina 6

10 Programming instruction Refer to the next page, the steps of programming are: 1. Scan the SETUP bar code on the parameter setting part. 2. Enter

Pagina 7

11 Operate the scanner by receiving command via UART Note: 1- The information in this chapter is provided for the scanner with RS232 cable or USB c

Pagina 8 - Decode zone

12 Interface selection This scanner supports interfaces such as keyboard wedge, RS-232 serial wedge, and USB interface. In most of the cases, simpl

Pagina 9 - Dimensions

13 Keyboard wedge Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard layo

Pagina 10 - Parts of the scanner

14 SETUP Option bar code Option Alpha. entry Keyboard layout USA Turkish F Turkish Q French Italian Spanish Slovak Denmark Japanese German 00*

Pagina 11 - Introduction to installation

15 RS-232 interface Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking protoc

Pagina 12 - Installation - USB

i Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including

Pagina 13 - Scanning modes

16 SETUP Option bar code Option Alpha. entry Flow control None RTS/CTS (Host idle: Low RTS) RTS/CTS (Host idle: High RTS) XON/XOFF ACK/NAK 00

Pagina 14 - Programming instruction

17 USB interface USB device type: HID keyboard– By setting, the scanner is used as a USB HID keyboard emulation device. The keyboard

Pagina 15

18 SETUP Option bar code Option Alpha. entry USB device type HID keyboard HID keyboard for Apple Mac USB virtual COM 00* 01 02 Keyboard layout

Pagina 16 - Interface selection

19 Hand-held scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. T

Pagina 17 - Keyboard wedge

20 i.e. in ASCII from 20H to 7EH. Alphanumeric character only- If this option is selected, the scanner will output the alphanumeric chara

Pagina 18

21 SETUP Option bar code Option Alpha. entry Scanning mode Good-read off Momentary Alternate continue Continue Timeout off 00 01* 02 03 04

Pagina 19 - RS-232 interface

22 Indication Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each

Pagina 20

23 Auto-detection scan Auto-detect sensor: By setting Enable, the scanner will start operating if any nearby object has been detected. The lase

Pagina 21 - USB interface

24 UPC-A Read: Format System Character Data digits (10 digits) Check digitCheck digit verification: The check digit is optional. Check digit trans.: B

Pagina 22

25 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Di

Pagina 23

ii Contents Technical specifications ...

Pagina 24

26 UPC-E Read: Format System Character “0” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the

Pagina 25

27 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Dis

Pagina 26 - Indication

28 UPC-E1 Read: Format System Character “1” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the

Pagina 27 - Auto-detection scan

29 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit trans. Di

Pagina 28

30 EAN-13 (ISBN/ISSN) Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of t

Pagina 29

31 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00 01* Check digit transmiss

Pagina 30

32 EAN-8 Read: Format Data digits (7 digits) Check digitCheck digit verification: The check digit is optional and made as the sum of the numerical va

Pagina 31

33 Code 39 (Code 32, Trioptic Code 39) Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆Check digit verification: The check digit is op

Pagina 32

34 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00* 01 Check digit transmissi

Pagina 33

35 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module

Pagina 34 - EAN-13 (ISBN/ISSN)

iii China Finance ...

Pagina 35

36 Industrial 2 of 5 Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to C

Pagina 36

37 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of

Pagina 37 - $ Data digits (6 digits) $

38 Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum module

Pagina 38 - “⋆” as data character

39 Code 128 Read: Format Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum module 103 of all

Pagina 39 - Interleaved 2 of 5

40 ISBT 128 Read: Format “=” or “&” Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum mod

Pagina 40 - Industrial 2 of 5

41 Code 93 Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The check digit is made as the sum module 47 of the

Pagina 41 - Matrix 2 of 5

42 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)Check digit verification: The check digit is present

Pagina 42 - Codabar

43 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey h

Pagina 43 - Code 128

44 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The UK/Plessey has one or two optional check dig

Pagina 44 - ISBT 128

45 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of

Pagina 45 - Code 93

1 Technical specifications Table 1-1 Technical specifications Input voltage 5 VDC ± 0.25V Power 500 mW (Operating); 650 mW (Max.) Current 100 mA (Oper

Pagina 46 - Code 11

46 China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of Code 39. The code length of China Post is 11. C

Pagina 47 - MSI/Plessey

47 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, exce

Pagina 48 - UK/Plessey

48 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion g

Pagina 49 - UCC/EAN 128

49 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer t

Pagina 50 - China Post

50 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the sym

Pagina 51

51 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Max. code length 00-99 00-99 10* Min. code length 00-99 00-99 10*

Pagina 52 - GS1 DataBar Limited

52 G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID

Pagina 53 - GS1 DataBar Expanded

53 FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substitu

Pagina 54 - China Finance

54 SETUP Option bar code Option Alpha. entry Prefix string setting 0-22 characters None 00-FF16 00* Suffix string setting 0-22 characters <EN

Pagina 55

55 G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code I

Pagina 56

2 Cable connector pin-outs descriptions Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connector on the s

Pagina 57

56 String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission

Pagina 58

57 SETUP Option bar code Option Alpha. entry Prefix transmission Disable Enable 00* 01 Suffix transmission Disable Enable 00 01* Code name transm

Pagina 59

58 Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disable

Pagina 60 - String transmission

59 Test Chart (Continued) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) G

Pagina 61

60 Troubleshooting Problem Possible causes Possible solutions No power to the scanner. Check the system power. Ensure the power supply is connected.

Pagina 62 - Test Chart

61 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not allo

Pagina 63 - Test Chart (Continued)

62 Assembling the stand 1. See the figure above, tighten the screws. 2. Bend the neck to the desired position for scanning. 3. Screw mounting: S

Pagina 64 - Troubleshooting

63 ASCII Table for keyboard wedge for RS-232 H L 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right

Pagina 65 - Maintenance

64 Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method

Pagina 66 - Assembling the stand

65 Return default parameters & others WARNING: Default value initialization If you wish to return the scanner to all the factory default setti

Pagina 67 - ASCII Table

3 Default setting for each barcode Table 2 Default setting for each barcode Code type Read enable Check digit verification Check digit transmissionMin

Pagina 68

66 Configuration alphanumeric entry barcode

Pagina 69

4 Decode zone High-density series Long-range series

Pagina 70

5 Dimensions

Comentarios a estos manuales

Sin comentarios